Simple Basement Egress 8 Reinforced Retaining Concrete Wall Design Drawing
Apr 15 2019 explore karen foster s board basement egress on pinterest.
Simple basement egress 8 reinforced retaining concrete wall design drawing. Concrete strength al ൯ne for an 10 thick wall with 5 10 and 2 5 clear to strength steel will only reduce the nominal moment capacity of the secti對on from 136 68 to 135 66 inch kips 尩 if the concrete strength decreased from 3 5 to 3 0 ksi. Walls generally concrete block basement walls are built without reinforcing steel. A sideways force against a basement wall puts one face of the wall in tension see figure 1 next page and concrete s tensile strength is much lower than its compressive strength. The walls are designed using parameters relevant to the london clay.
Download free high quality cad drawings blocks and details of retaining walls organized by masterformat. Aci e702 example problems buried concrete basement wall page 3 of 9 calculations references overview of aci 318 chapter 14 walls requirements design shall satisfy sections 14 2 and 14 3 plus 14 4 14 5 or 14 8. Even though no water table was found the walls will be designed for a water table 2 00m above. Designing a basement egress window.
See more ideas about egress basement basement windows. O section 14 2 described the general requirements o section 14 3 provides minimum reinforcement requirements. Steel is required only if the soil exerts extreme lateral pressures loads are unusually heavy the basement is built more than 8 feet below grade or there s seismic risk. If such obstacles are present in your home plan a new route for any pathway that would have to be disturbed by the construction.
Building codes and retaining walls 5. Designing a wall to prevent failure in bending requires a proper analysis of the soil loads and an appropriate structural design of the wall. Retaining wall design 10 editionth a design guide for earth retaining structures contents at a glance. In this example the structural design of the three retaining wall components is performed by hand.
F c 3000 psi fy 60 ksi natural soil development of structural design equations. In seismic zones 2 3 and 4 ubc requires fully reinforced construction. Soil bearing and stability 8. Design procedure overview 3.
Soil mechanics simplified 4. Forces on retaining walls 6. Earthquake seismic design 7. Structural design principles basement walls basement walls are designed as propped cantilevers in reinforced concrete the basement slab acting as the prop at base level.